Description

Main
range of productAltivar Process ATV600

product or component typeVariable speed drive

product specific applicationProcess and utilities

device short nameATV630

variantStandard version

product destinationAsynchronous motors
Synchronous motors

EMC filterWithout EMC filter

IP degree of protectionIP21 conforming to IEC 61800-5-1
IP21 conforming to IEC 60529

degree of protectionUL type 1 conforming to UL 508C

type of coolingForced convection

supply frequency50...60 Hz - 5...5 %

network number of phases3 phases

[Us] rated supply voltage200...240 V - 15...10 %

motor power kW5.5 kW (normal duty)
4 kW (heavy duty)

motor power hp7.5 hp normal duty
5 hp heavy duty

line current20.2 A at 200 V (normal duty)
17.1 A at 240 V (normal duty)
15.1 A at 200 V (heavy duty)
13 A at 240 V (heavy duty)

prospective line Isc50 kA

apparent power7.1 kVA at 240 V (normal duty)
5.4 kVA at 240 V (heavy duty)

continuous output current25.4 A at 4 kHz for normal duty
18.7 A at 4 kHz for heavy duty

maximum transient current27.9 A during 60 s (normal duty)
28.1 A during 60 s (heavy duty)

asynchronous motor control profileOptimized torque mode
Constant torque standard
Variable torque standard

synchronous motor control profilePermanent magnet motor
Synchronous reluctance motor

output frequency0.0001…0.5 kHz

speed drive output frequency0.1…599 Hz

nominal switching frequency4 kHz

switching frequency2...12 kHz adjustable
4...12 kHz with derating factor

safety functionSTO (safe torque off) SIL 3

discrete input logic16 preset speeds

communication port protocolModbus serial
Modbus TCP
Ethernet

option cardSlot A: communication module, Profibus DP V1
Slot A: communication module, Profinet
Slot A: communication module, DeviceNet
Slot A: communication module, Modbus TCP/EtherNet/IP
Slot A: communication module, CANopen daisy chain RJ45
Slot A: communication module, CANopen SUB-D 9
Slot A: communication module, CANopen screw terminals
Slot A/slot B: digital and analog I/O extension module
Slot A/slot B: output relay extension module
Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link
Communication module, BACnet MS/TP
Communication module, Ethernet Powerlink

Complementary
output voltage<= power supply voltage

permissible temporary current boost1.1 x In during 60 s (normal duty)
1.5 x In during 60 s (heavy duty)

motor slip compensationCan be suppressed
Not available in permanent magnet motor law
Adjustable
Automatic whatever the load

acceleration and deceleration rampsLinear adjustable separately from 0.01...9999 s

braking to standstillBy DC injection

protection typeThermal protection: motor
Safe torque off: motor
Motor phase break: motor
Thermal protection: drive
Safe torque off: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive

frequency resolutionDisplay unit: 0.1 Hz
Analog input: 0.012/50 Hz

electrical connectionControl: removable screw terminals0.5...1.5 mm²/AWG 20...AWG 16
Motor: screw terminal10 mm²/AWG 8
Line side: screw terminal6 mm²/AWG 10

connector typeRJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP
RJ45 (on the remote graphic terminal) for Modbus serial

physical interface2-wire RS 485 for Modbus serial

transmission frameRTU for Modbus serial

transmission rate10/100 Mbit/s for Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial

exchange modeHalf duplex, full duplex, autonegotiation Ethernet/Modbus TCP

data format8 bits, configurable odd, even or no parity for Modbus serial

type of polarizationNo impedance for Modbus serial

number of addresses1…247 for Modbus serial

method of accessSlave Modbus TCP

supplyExternal supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection

local signalling3 LEDslocal diagnostic:
3 LEDs (dual colour)embedded communication status:
4 LEDs (dual colour)communication module status:
1 LED (red)presence of voltage:

width171 mm

height409 mm

depth233 mm

net weight7.7 kg

analogue input number3

analogue input typeAI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits

discrete input number8

discrete input typeDI1...DI6 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm

input compatibilityDI1...DI6: discrete input level 1 PLC conforming to EN/IEC 61131-2
DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68
STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2

discrete input logicPositive logic (source) (DI1...DI6), < 5 V (state 0), > 11 V (state 1)
Negative logic (sink) (DI1...DI6), > 16 V (state 0), < 10 V (state 1)
Positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1)
Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)

analogue output number2

analogue output typeSoftware-configurable voltage AO1, AO2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Software-configurable current AO1, AO2: 0...20 mA, resolution 10 bits

sampling duration2 ms +/- 0.5 ms (DI1...DI4) - discrete input
5 ms +/- 1 ms (DI5, DI6) - discrete input
5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input
10 ms +/- 1 ms (AO1) - analog output

accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output

linearity errorAI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AO1, AO2: +/- 0.2 % for analog output

relay output number3

relay output typeConfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles

refresh timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)

minimum switching currentRelay output R1, R2, R3: 5 mA at 24 V DC

maximum switching currentRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC

isolationBetween power and control terminals

Variable speed drive application selectionBuilding - HVAC Compressor centrifugal
Food and beverage processing Other application
Mining mineral and metal Fan
Mining mineral and metal Pump
Oil and gas Fan
Water and waste water Other application
Building - HVAC Screw compressor
Food and beverage processing Pump
Food and beverage processing Fan
Food and beverage processing Atomization
Oil and gas Electro submersible pump (ESP)
Oil and gas Water injection pump
Oil and gas Jet fuel pump
Oil and gas Compressor for refinery
Water and waste water Centrifuge pump
Water and waste water Positive displacement pump
Water and waste water Electro submersible pump (ESP)
Water and waste water Screw pump
Water and waste water Lobe compressor
Water and waste water Screw compressor
Water and waste water Compressor centrifugal
Water and waste water Fan
Water and waste water Conveyor
Water and waste water Mixer

Motor power range AC-34…6 kW at 200…240 V 3 phases

mounting modeWall mount

Environment
insulation resistance> 1 MOhm 500 V DC for 1 minute to earth

noise level56 dB conforming to 86/188/EEC

power dissipation in WNatural convection: 47 W at 200 V, switching frequency 4 kHz
Forced convection: 179 W at 200 V, switching frequency 4 kHz

volume of cooling air103 m3/h

operating positionVertical +/- 10 degree

maximum THDI<48 % from 80...100 % of load conforming to IEC 61000-3-12

electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6

pollution degree2 conforming to EN/IEC 61800-5-1

vibration resistance1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6

shock resistance15 gn for 11 ms conforming to IEC 60068-2-27

relative humidity5…95 % without condensation conforming to IEC 60068-2-3

ambient air temperature for operation-15…50 °C (without derating)
50…60 °C (with derating factor)

ambient air temperature for storage-40…70 °C

operating altitude<= 1000 m without derating
1000...4800 m with current derating 1 % per 100 m

environmental characteristicChemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3

standardsUL 508C
EN/IEC 61800-3
Environment 1 category C2 EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1

product certificationsUL
ATEX zone 2/22
CSA
DNV-GL
REACH
TÜV
ATEX INERIS

markingCE

Packing Units
Unit Type of Package 1PCE

Number of Units in Package 11

Package 1 Weight10.203 kg

Package 1 Height21.5 cm

Package 1 width58 cm

Package 1 Length35 cm

Unit Type of Package 2P06

Number of Units in Package 23

Package 2 Weight43.61 kg

Package 2 Height80 cm

Package 2 width80 cm

Package 2 Length60 cm

0
0
104