Description

Main
rangeTeSys

product nameTeSys F

product or component typeContactor

device short nameLC1F

contactor applicationMotor control
Resistive load

utilisation categoryAC-3
AC-1
AC-4

poles description3P

power pole contact composition3 NO

[Ue] rated operational voltage<= 1000 V AC 50/60 Hz
<= 460 V DC

[Ie] rated operational current1000 A (at <40 °C) at <= 440 V AC AC-1
630 A (at <55 °C) at <= 440 V AC AC-3

motor power kW335 kW at 380...400 V AC 50/60 Hz (AC-3)
375 kW at 415 V AC 50/60 Hz (AC-3)
400 kW at 440 V AC 50/60 Hz (AC-3)
400 kW at 500 V AC 50/60 Hz (AC-3)
450 kW at 660...690 V AC 50/60 Hz (AC-3)
450 kW at 1000 V AC 50/60 Hz (AC-3)
200 kW at 220...230 V AC 50/60 Hz (AC-3)
100 kW at 400 V AC 50/60 Hz (AC-4)

[Uc] control circuit voltage380 V AC 40...400 Hz

Complementary
[Uimp] rated impulse withstand voltage8 kV

overvoltage categoryIII

[Ith] conventional free air thermal current1000 A (at 40 °C)
1250 A

rated breaking capacity5040 A conforming to IEC 60947-4-1

[Icw] rated short-time withstand current5050 A 40 °C - 10 s
4400 A 40 °C - 30 s
3400 A 40 °C - 1 min
2200 A 40 °C - 3 min
1600 A 40 °C - 10 min

associated fuse rating1000 A gG at <= 440 V
630 A aM at <= 440 V

average impedance0.12 mOhm - Ith 1000 A 50 Hz

[Ui] rated insulation voltage1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C

power dissipation per pole120 W AC-1
48 W AC-3

mounting supportPlate

standardsEN 60947-1
JIS C8201-4-1
IEC 60947-4-1
IEC 60947-1
EN 60947-4-1

product certificationsUL
CCC
RINA
CB
DNV
BV
ABS
RMRoS
LROS (Lloyds register of shipping)

connections - terminalsControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: bar 2 cable(s) - busbar cross section: 60 x 5 mm
Power circuit: bolted connection

tightening torqueControl circuit: 1.2 N.m
Power circuit: 58 N.m

control circuit voltage limitsOperational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)
Drop-out: 0.25...0.5 Uc 40...400 Hz (at 55 °C)

inrush power in VA1650 VA 40...400 Hz cos phi 0.9 (at 20 °C)

hold-in power consumption in VA22 VA 40...400 Hz cos phi 0.9 (at 20 °C)

heat dissipation20 W

operating time40...80 ms closing
100...200 ms opening

mechanical durability5 Mcycles

maximum operating rate1200 cyc/h 55 °C

compatibility codeLC1F

0
0
27